@article {991, title = {HYDI-DSI revisited: constrained non-parametric EAP imaging without q-space re-gridding}, journal = {Medical Image Analysis}, volume = {84}, year = {2023}, month = {02/2023}, chapter = {102728}, abstract = {
Hybrid Diffusion Imaging (HYDI) was one of the first attempts to use multi-shell samplings of the q-space to infer diffusion properties beyond Diffusion Tensor Imaging (DTI) or High Angular ResolutionDiffusion Imaging (HARDI). HYDI was intended as a flexible protocol embedding both DTI (for lower b-values) and HARDI (for higher b-values) processing, as well as Diffusion Spectrum Imaging (DSI) when the entire data set was exploited. In the latter case, the spherical sampling of the q-space is re-gridded by interpolation to a Cartesian lattice whose extent covers the range of acquired b-values, hence being acquisition-dependent. The Discrete Fourier Transform (DFT) is afterwards used to compute the corresponding Cartesian sampling of the Ensemble Average Propagator (EAP) in an entirely non-parametric way. From this lattice, diffusion markers such as the Return To Origin Probability (RTOP) or the Mean Squared Displacement (MSD) can be numerically estimated.
We aim at re-formulating this scheme by means of a Fourier Transform encoding matrix that eliminates the need for q-space re-gridding at the same time it preserves the non-parametric nature of HYDI-DSI. The encoding matrix is adaptively designed at each voxel according to the underlying DTI approximation, so that an optimal sampling of the EAP can be pursued without being conditioned by the particular acquisition protocol. The estimation of the EAP is afterwards carried out as a regularized Quadratic Programming (QP) problem, which allows to impose positivity constraints that cannot be trivially embedded within the conventional HYDI-DSI. We demonstrate that the definition of the encoding matrix in the adaptive space allows to analytically (as opposed to numerically) compute several popular descriptors of diffusion with the unique source of error being the cropping of high frequency harmonics in the Fourier analysis of the attenuation signal. They include not only RTOP and MSD, but also Return to Axis/Plane Probabilities (RTAP/RTPP), which are defined in terms of specific spatial directions and are not available with the former HYDI-DSI. We report extensive experiments that suggest the benefits of our proposal in terms of accuracy, robustness and computational efficiency, especially when only standard, non-dedicated q-space samplings are available.
The objective of this study is to evaluate the efficacy of deep learning (DL) techniques in improving the quality of diffusion MRI (dMRI) data in clinical applications. The study aims to determine whether the use of artificial intelligence (AI) methods in medical images may result in the loss of critical clinical information and/or the appearance of false information. To assess this, the focus was on the angular resolution of dMRI and a clinical trial was conducted on migraine, specifically between episodic and chronic migraine patients. The number of gradient directions had an impact on white matter analysis results, with statistically significant differences between groups being drastically reduced when using 21 gradient directions instead of the original 61. Fourteen teams from different institutions were tasked to use DL to enhance three diffusion metrics (FA, AD and MD) calculated from data acquired with 21 gradient directions and a b-value of 1000 s/mm2. The goal was to produce results that were comparable to those calculated from 61 gradient directions. The results were evaluated using both standard image quality metrics and Tract-Based Spatial Statistics (TBSS) to compare episodic and chronic migraine patients. The study results suggest that while most DL techniques improved the ability to detect statistical differences between groups, they also led to an increase in false positive. The results showed that there was a constant growth rate of false positives linearly proportional to the new true positives, which highlights the risk of generalization of AI-based tasks when assessing diverse clinical cohorts and training using data from a single group. The methods also showed divergent performance when replicating the original distribution of the data and some exhibited significant bias. In conclusion, extreme caution should be exercised when using AI methods for harmonization or synthesis in clinical studies when processing heterogeneous data in clinical studies, as important information may be altered, even when global metrics such as structural similarity or peak signal-to-noise ratio appear to suggest otherwise.
}, keywords = {Angular resolution, Artificial Intelligence, Deep learning, Diffusion tensor, diffusion MRI, machine learning}, issn = {2213-1582}, doi = {https://doi.org/10.1016/j.nicl.2023.103483}, url = {https://www.sciencedirect.com/science/article/pii/S2213158223001742}, author = {Santiago Aja-Fern{\'a}ndez and Carmen Mart{\'\i}n-Mart{\'\i}n and {\'A}lvaro Planchuelo-G{\'o}mez and Abrar Faiyaz and Md Nasir Uddin and Giovanni Schifitto and Abhishek Tiwari and Saurabh J. Shigwan and Rajeev Kumar Singh and Tianshu Zheng and Zuozhen Cao and Dan Wu and Stefano B. Blumberg and Snigdha Sen and Tobias Goodwin-Allcock and Paddy J. Slator and Mehmet Yigit Avci and Zihan Li and Berkin Bilgic and Qiyuan Tian and Xinyi Wang and Zihao Tang and Mariano Cabezas and Amelie Rauland and Dorit Merhof and Renata Manzano Maria and Vin{\'\i}cius Paran{\'\i}ba Campos and Tales Santini and Marcelo Andrade da Costa Vieira and SeyyedKazem HashemizadehKolowri and Edward DiBella and Chenxu Peng and Zhimin Shen and Zan Chen and Irfan Ullah and Merry Mani and Hesam Abdolmotalleby and Samuel Eckstrom and Steven H. Baete and Patryk Filipiak and Tanxin Dong and Qiuyun Fan and Rodrigo de Luis-Garc{\'\i}a and Antonio Trist{\'a}n-Vega and Tomasz Pieciak} } @article {934, title = {Accurate free-water estimation in white matter from fast diffusion MRI acquisitions using the spherical means technique}, journal = {Magnetic Resonance in Medicine}, volume = {87}, year = {2021}, month = {2022}, pages = {1028-1035}, type = {Techncial Note}, abstract = {Purpose To accurately estimate the partial volume fraction of free water in the white matter from diffusion MRI acquisitions not demanding strong sensitizing gradients and/or large collections of different b-values. Data sets considered comprise 32-64 gradients near plus 6 gradients near . Theory and Methods The spherical means of each diffusion MRI set with the same b-value are computed. These means are related to the inherent diffusion parameters within the voxel (free- and cellular-water fractions; cellular-water diffusivity), which are solved by constrained nonlinear least squares regression. Results The proposed method outperforms those based on mixtures of two Gaussians for the kind of data sets considered. W.r.t. the accuracy, the former does not introduce significant biases in the scenarios of interest, while the latter can reach a bias of 5\%{\textendash}7\% if fiber crossings are present. W.r.t. the precision, a variance near , compared to 15\%, can be attained for usual configurations. Conclusion It is possible to compute reliable estimates of the free-water fraction inside the white matter by complementing typical DTI acquisitions with few gradients at a lowb-value. It can be done voxel-by-voxel, without imposing spatial regularity constraints.
}, keywords = {diffusion MRI, free water, spherical means, white matter}, doi = {https://doi.org/10.1002/mrm.28997}, author = {Antonio Trist{\'a}n-Vega and Guillem Par{\'\i}s and Rodrigo de Luis-Garc{\'\i}a and Santiago Aja-Fern{\'a}ndez} } @article {899, title = {Apparent propagator anisotropy from single-shell diffusion MRI acquisitions}, journal = {Magnetic Resonance in Medicine}, volume = {85}, year = {2021}, month = {2021}, pages = {2869-2881}, chapter = {2869}, doi = {https://doi.org/10.1002/mrm.28620}, url = {https://onlinelibrary.wiley.com/doi/abs/10.1002/mrm.28620}, author = {Santiago Aja-Fern{\'a}ndez and Antonio Trist{\'a}n-Vega and Derek K. Jones} } @article {900, title = {Efficient and accurate EAP imaging from multi-shell dMRI with Micro-Structure adaptive convolution kernels and dual Fourier Integral Transforms (MiSFIT)}, journal = {NeuroImage}, volume = {227}, year = {2021}, month = {2021}, pages = {117616}, issn = {1053-8119}, doi = {https://doi.org/10.1016/j.neuroimage.2020.117616}, url = {http://www.sciencedirect.com/science/article/pii/S1053811920311010}, author = {Antonio Trist{\'a}n-Vega and Santiago Aja-Fern{\'a}ndez} } @proceedings {856, title = {AMURA with standard single-shell acquisition can detect changes beyond the Diffusion Tensor: a migraine clinical study}, volume = {4549}, year = {2020}, month = {2020}, abstract = {AMURA (Apparent Measures Using Reduced Acquisitions) is an alternative formulation to drastically reduce the number of samples needed for the estimation of diffusion properties related to the Ensemble Average diffusion Propagator (EAP). Although these measures were initially intended for medium-to-high b-values, in this work we evaluate their performance in DTI-like acquisitions. Fifty healthy controls, 54 episodic migraine (EM) and 56 chronic migraine (CM) patients were compared, using a single-shell diffusion scheme at b=1000 s/mm2. We compare AMURA measures (return-to-origin, return-to-axis and return-to-plane probabilities) to traditional DTI measures. Differences between EM and controls were only detectable using the return-to-origin probability.}, author = {{\'A}lvaro Planchuelo-G{\'o}mez and Rodrigo de Luis-Garc{\'\i}a and Antonio Trist{\'a}n-Vega and Garc{\'\i}a-Azor{\'\i}n, David and {\'A}ngel L. Guerrero and Santiago Aja-Fern{\'a}ndez} } @inbook {895, title = {Alternative Diffusion Anisotropy Metric from Reduced MRI Acquisitions}, booktitle = {Computational Diffusion MRI}, year = {2020}, pages = {13{\textendash}24}, publisher = {Springer, Cham}, organization = {Springer, Cham}, author = {Santiago Aja-Fern{\'a}ndez and Antonio Trist{\'a}n-Vega and Rodrigo de Luis-Garc{\'\i}a and Derek K. Jones} } @article {844, title = {Micro-structure diffusion scalar measures from reduced MRI acquisitions}, journal = {PLOS ONE}, volume = {15}, year = {2020}, month = {2020}, pages = {1-25}, abstract = {In diffusion MRI, the Ensemble Average diffusion Propagator (EAP) provides relevant micro-structural information and meaningful descriptive maps of the white matter previously obscured by traditional techniques like Diffusion Tensor Imaging (DTI). The direct estimation of the EAP, however, requires a dense sampling of the Cartesian q-space involving a huge amount of samples (diffusion gradients) for proper reconstruction. A collection of more efficient techniques have been proposed in the last decade based on parametric representations of the EAP, but they still imply acquiring a large number of diffusion gradients with different b-values (shells). Paradoxically, this has come together with an effort to find scalar measures gathering all the q-space micro-structural information probed in one single index or set of indices. Among them, the return-to-origin (RTOP), return-to-plane (RTPP), and return-to-axis (RTAP) probabilities have rapidly gained popularity. In this work, we propose the so-called {\textquotedblleft}Apparent Measures Using Reduced Acquisitions{\textquotedblright} (AMURA) aimed at computing scalar indices that can mimic the sensitivity of state of the art EAP-based measures to micro-structural changes. AMURA drastically reduces both the number of samples needed and the computational complexity of the estimation of diffusion properties by assuming the diffusion anisotropy is roughly independent from the radial direction. This simplification allows us to compute closed-form expressions from single-shell information, so that AMURA remains compatible with standard acquisition protocols commonly used even in clinical practice. Additionally, the analytical form of AMURA-based measures, as opposed to the iterative, non-linear reconstruction ubiquitous to full EAP techniques, turns the newly introduced apparent RTOP, RTPP, and RTAP both robust and efficient to compute.
}, doi = {10.1371/journal.pone.0229526}, url = {https://doi.org/10.1371/journal.pone.0229526}, author = {Santiago Aja-Fern{\'a}ndez and Rodrigo de Luis-Garc{\'\i}a and Maryam Afzali and Molendowska, Malwina and Tomasz Pieciak and Antonio Trist{\'a}n-Vega} } @inbook {818, title = {Return-to-Axis Probability Calculation from Single-Shell Acquisitions}, booktitle = {Computational Diffusion MRI}, year = {2019}, pages = {29-41}, publisher = {Springer}, organization = {Springer}, isbn = {978-3-030-05830-2}, doi = {10.1007/978-3-030-05831-9_3}, author = {Santiago Aja-Fern{\'a}ndez and Antonio Trist{\'a}n-Vega and Molendowska, Malwina and Tomasz Pieciak and Luis-Garc{\'\i}a, Rodrigo} } @conference {815, title = {Single-Shell Return-to-the-Origin Probability Diffusion Mri Measure Under a Non-Stationary Rician Distributed Noise}, booktitle = {2019 IEEE 16th International Symposium on Biomedical Imaging (ISBI 2019)}, year = {2019}, publisher = {IEEE}, organization = {IEEE}, author = {Tomasz Pieciak and Bogusz, Fabian and Antonio Trist{\'a}n-Vega and Rodrigo de Luis-Garc{\'\i}a and Santiago Aja-Fern{\'a}ndez} } @conference {800, title = {Compressed UAV sensing for flood monitoring by solving the continuous travelling salesman problem over hyperspectral maps}, booktitle = {Remote Sensing of the Ocean, Sea Ice, Coastal Waters, and Large Water Regions 2018}, year = {2018}, publisher = {International Society for Optics and Photonics}, organization = {International Society for Optics and Photonics}, author = {Pablo Casaseca-de-la-Higuera and Antonio Trist{\'a}n-Vega and Hoyos-Barcel{\'o}, Carlos and S. Merino-Caviedes and Wang, Qi and Luo, Chunbo and Wang, Xinheng and Wang, Zhi} } @proceedings {759, title = {Return-to-the-origin probability calculation in single shell acquisitions}, year = {2018}, pages = {1414}, address = {Paris, France}, author = {Santiago Aja-Fern{\'a}ndez and Antonio Trist{\'a}n-Vega and Malwina Molendowska and Tomasz Pieciak and Rodrigo de Luis-Garc{\'\i}a} } @article {781, title = {Scalar diffusion-MRI measures invariant to acquisition parameters: A first step towards imaging biomarkers}, journal = {Magnetic Resonance Imaging}, volume = {54}, year = {2018}, month = {2018}, pages = {194 - 213}, issn = {0730-725X}, doi = {https://doi.org/10.1016/j.mri.2018.03.001}, url = {http://www.sciencedirect.com/science/article/pii/S0730725X18300262}, author = {Santiago Aja-Fern{\'a}ndez and Tomasz Pieciak and Antonio Trist{\'a}n-Vega and Gonzalo Vegas-S{\'a}nchez-Ferrero and Vicente Molina and Rodrigo de Luis-Garc{\'\i}a} } @article {627, title = {Adjugate Diffusion Tensors for Geodesic Tractography in White Matter}, journal = {Journal of Mathematical Imaging and Vision}, volume = {54}, year = {2015}, pages = {1{\textendash}14}, abstract = {One of the approaches in diffusion tensor imaging is to consider a Riemannian metric given by the inverse diffusion tensor. Such a metric is used for geodesic tractography and connectivity analysis in white matter. We propose a metric tensor given by the adjugate rather than the previously proposed inverse diffusion tensor. The adjugate metric can also be employed in the sharpening framework. Tractography experiments on synthetic and real brain diffusion data show improvement for high-curvature tracts and in the vicinity of isotropic diffusion regions relative to most results for inverse (sharpened) diffusion tensors, and especially on real data. In addition, adjugate tensors are shown to be more robust to noise.
}, issn = {1573-7683}, doi = {10.1007/s10851-015-0586-8}, url = {http://dx.doi.org/10.1007/s10851-015-0586-8}, author = {Andrea Fuster and Tom Dela-Haije and Antonio Trist{\'a}n-Vega and Birgit Plantinga and Carl-Fredik Westin and Luc Florack} } @article {628, title = {Efficient and Robust Image Restoration Using Multiple-Feature L2-Relaxed Sparse Analysis Priors}, journal = {IEEE Transactions on Image Processing}, volume = {24}, year = {2015}, month = {Dec}, pages = {5046-5059}, abstract = {We propose a novel formulation for relaxed analysis-based sparsity in multiple dictionaries as a general type of prior for images, and apply it for Bayesian estimation in image restoration problems. Our formulation of a l2 -relaxed l0 pseudo-norm prior allows for an especially simple maximum a posteriori estimation iterative marginal optimization algorithm, whose convergence we prove. We achieve a significant speedup over the direct (static) solution by using dynamically evolving parameters through the estimation loop. As an added heuristic twist, we fix in advance the number of iterations, and then empirically optimize the involved parameters according to two performance benchmarks. The resulting constrained dynamic method is not just fast and effective, it is also highly robust and flexible. First, it is able to provide an outstanding tradeoff between computational load and performance, in visual and objective, mean square error and structural similarity terms, for a large variety of degradation tests, using the same set of parameter values for all tests. Second, the performance benchmark can be easily adapted to specific types of degradation, image classes, and even performance criteria. Third, it allows for using simultaneously several dictionaries with complementary features. This unique combination makes ours a highly practical deconvolution method.
}, keywords = {Bayes methods, Bayesian estimation, Convergence, Dictionaries, Estimation, Kernel, L2-relaxed L0 pseudo norm, L2-relaxed L0 pseudo-norm prior, L2-relaxed sparse analysis priors, Maximum likelihood estimation, Optimization, Redundancy, computational load, constrained dynamic method, deconvolution, deconvolution method, dynamically evolving parameters, estimation loop, fast constrained dynamic algorithm, image restoration, iterative marginal optimization, iterative methods, maximum a posteriori estimation, mean square error, mean square error methods, multiple representations, multiple-feature L2-relaxed sparse analysis priors, optimisation, robust tunable parameters, structural similarity terms}, issn = {1057-7149}, doi = {10.1109/TIP.2015.2478405}, author = {Javier Portilla and Antonio Trist{\'a}n-Vega and Ivan W. Selesnick} } @article {567, title = {Impact of MR Acquisition Parameters on DTI Scalar Indexes: A Tractography Based Approach}, journal = {PLoS ONE}, volume = {10}, year = {2015}, pages = {e0137905}, doi = {10.1371/journal.pone.0137905}, url = {http://dx.doi.org/10.1371\%2Fjournal.pone.0137905}, author = {Gonzalo Barrio-Arranz and Rodrigo de Luis-Garc{\'\i}a and Antonio Trist{\'a}n-Vega and Marcos Mart{\'\i}n-Fern{\'a}ndez and Santiago Aja-Fern{\'a}ndez} } @article {532, title = {Improving GRAPPA reconstruction by frequency discrimination in the ACS lines}, journal = {International Journal of Computer Assisted Radiology and Surgery}, volume = {10}, year = {2015}, month = {2015}, pages = {1699-1710}, chapter = {1699}, abstract = {An end-to-end system to automate the well-known Tanner - Whitehouse (TW3) clinical procedure to estimate the skeletal age in childhood is proposed. The system comprises the detailed analysis of the two most important bones in TW3: the radius and ulna wrist bones. First, a modified version of an adaptive clustering segmentation algorithm is presented to properly semi-automatically segment the contour of the bones. Second, up to 89 features are defined and extracted from bone contours and gray scale information inside the contour, followed by some well-founded feature selection mathematical criteria, based on the ideas of maximizing the classes{\textquoteright} separability. Third, bone age is estimated with the help of a Generalized Softmax Perceptron (GSP) neural network (NN) that, after supervised learning and optimal complexity estimation via the application of the recently developed Posterior Probability Model Selection (PPMS) algorithm, is able to accurately predict the different development stages in both radius and ulna from which and with the help of the TW3 methodology, we are able to conveniently score and estimate the bone age of a patient in years, in what can be understood as a multiple-class (multiple stages) pattern recognition approach with posterior probability estimation. Finally, numerical results are presented to evaluate the system performance in predicting the bone stages and the final patient bone age over a private hand image database, with the help of the pediatricians and the radiologists expert diagnoses. {\^A}{\textcopyright} 2006 IEEE.
}, keywords = {Age Determination by Skeleton, Aging, Algorithms, Artificial Intelligence, Automated, Bone, Bone age assessment, Clustering algorithms, Computer-Assisted, Humans, Model selection, Neural networks, Pattern recognition, Radiographic Image Interpretation, Reproducibility of Results, Sensitivity and Specificity, Skeletal maturity, algorithm, article, artificial neural network, automation, bone age, bone maturation, childhood, instrumentation, radius, ulna}, issn = {00189294}, doi = {10.1109/TBME.2008.918554}, url = {http://www.scopus.com/inward/record.url?eid=2-s2.0-42249094547\&partnerID=40\&md5=2cecfea5f75a61b048611f2391b00aed}, author = {Antonio Trist{\'a}n-Vega and J I Arribas} } @conference {479, title = {Ultrasound Based Intraoperative Brain Shift Correction}, booktitle = {Ultrasonics Symposium, 2007. IEEE}, year = {2007}, publisher = {IEEE}, organization = {IEEE}, author = {Gonz{\'a}lez, Javier and Dario Sosa-Cabrera and Ortega, Mario and Gil, Jose Antonio and Antonio Trist{\'a}n-Vega and Emma Mu{\~n}oz-Moreno and Rodrigo de Luis-Garc{\'\i}a} } @proceedings {cardenes2007usimagtool, title = {Usimagtool: an open source freeware software for ultrasound imaging and elastography}, year = {2007}, pages = {117{\textendash}127}, author = {Rub{\'e}n C{\'a}rdenes-Almeida and Antonio Trist{\'a}n-Vega and Ferrero, GVS and Santiago Aja-Fern{\'a}ndez} } @article {419, title = {A fast B-spline pseudo-inversion algorithm for consistent image registration}, journal = {Lecture Notes in Computer Science (including subseries Lecture Notes in Artificial Intelligence and Lecture Notes in Bioinformatics)}, volume = {4673 LNCS}, year = {2007}, pages = {768-775}, abstract = {Recently, the concept of consistent image registration has been introduced to refer to a set of algorithms that estimate both the direct and inverse deformation together, that is, they exchange the roles of the target and the scene images alternatively; it has been demonstrated that this technique improves the registration accuracy, and that the biological significance of the obtained deformations is also improved. When dealing with free form deformations, the inversion of the transformations obtained becomes computationally intensive. In this paper, we suggest the parametrization of such deformations by means of a cubic B-spline, and its approximated inversion using a highly efficient algorithm. The results show that the consistency constraint notably improves the registration accuracy, especially in cases of a heavy initial misregistration, with very little computational overload. {\^A}{\textcopyright} Springer-Verlag Berlin Heidelberg 2007.
}, keywords = {Approximation algorithms, Computational overload, Consistent registration, Constraint theory, Image registration, Inverse problems, Inverse transformation, Parameterization}, isbn = {9783540742715}, issn = {03029743}, url = {http://www.scopus.com/inward/record.url?eid=2-s2.0-38149022572\&partnerID=40\&md5=627751cd7654872cbd9ee74a249752eb}, author = {Antonio Trist{\'a}n-Vega and J I Arribas} } @conference {417, title = {A radius and ulna skeletal age assessment system}, booktitle = {2005 IEEE Workshop on Machine Learning for Signal Processing}, year = {2005}, address = {Mystic, CT}, abstract = {An end to end system to partially automate the TW3 bone age assessment procedure is proposed. The system comprises the detailed analysis of the two more important bones in TW3: the radius and ulna wrist bones. First, a generalization of K-means algorithm is presented to semi-automatically segment the contour of the bones and thus extract up to 89 features describing shapes and textures from bones. Second, a well-founded feature selection criterion based on the statistical properties of data is used in order to properly choose the most relevant features. Third, bone age is estimated with the help of a Generalized Softmax Perceptron (GSP) Neural Network (NN) whose optimal complexity is estimated via the Posterior Probability Model Selection (PPMS) algorithm. We can then predict the different development stages in both radius and ulna, from which we are able to score and estimate the bone age of a patient in years and finally we compare the NN results with those from the pediatrician expert discrepancies. {\^A}{\textcopyright} 2005 IEEE.
}, keywords = {Algorithms, Bone, Feature extraction, Generalized Softmax Perceptron (GSP), Living systems studies, Neural networks, Probability Model Selection (PPMS), Skeletal age assessment system}, isbn = {0780395174; 9780780395176}, doi = {10.1109/MLSP.2005.1532903}, url = {http://www.scopus.com/inward/record.url?eid=2-s2.0-33749052083\&partnerID=40\&md5=eefa29ac09f4efa304b613cf07ab8d10}, author = {Antonio Trist{\'a}n-Vega and J I Arribas} }